콘텐츠로 건너뛰기
tegam ®

2601A High Power RF Sensor

Active

High Power RF Transfer Standard, 250 kHz to 1000 MHz

Advanced Energy's 2601A high power RF transfer standards enable the precise measurement of RF power (2.5 W to 250 W) in the 250 kHz to 1000 MHz frequency range. 

The design is mounted on an aluminum heat sink to reduce changes in coupling factor attributable to heating.  These standards are highly accurate and stable with time and temperature.  They are ideal for use as standards for the transfer of calibration factors to other high power RF standards and sensors.

The calibration of these standards is traceable to the International System of Units (SI) through the National Institute of Standards and Technology (NIST) or other recognized National Metrology Institutes.

특징

  • 250 kHz to 1000 MHz frequency range
  • 2.5 to 250 W dynamic range (+34 to +54 dBm)
  • 1% basic accuracy

혜택

  • Enables calibration of high power RF sensors and meters
  • Compatible with TEGAM High Power RF Calibration System (HPC-250)

사양

Basic Accuracy/Linearity: 1.0% (typical)
Directivity: N/A
Frequency Range: 250 kHz to 1 GHz
Impedance (nominal): 50 Ohms
Insertion Loss: 0.5dB (typical)
Power Range (typical): 2.5 W to 250 W
Power Requirements: Thermistor Power Meter Required
Resolution (W): NA
모든 사양 사양 축소

재고 확인

모델 번호
Frequency Range Power Range (typical) Power Requirements 구매
2601A Active, 문의하기
RF Power Transfer Standard
250 kHz to 1 GHz 2.5 W to 250 W Thermistor Power Meter Required 구매

Accessories Stock Check

Cable, Voltage Bias and Heater, 1830A to 15XX/25XX, 15"

Heater cable (4-pin mini to 4-pin mini)
For use with the following combinations:
• 1806A connected to F1130A/B and F1135A/B
• 1830A connected to F1130A/B and F1135A/B

Cable, Voltage Bias and Heater, 1830A to 15XX/25XX, 48"

Heater cable (4-pin mini to 4-pin mini)
For use with the following combinations:
• 1806A connected to F1130A/B and F1135A/B
• 1830A connected to F1130A/B and F1135A/B

Power Sensor Calibration Accessories

PM Series Accessories

기술 문서

제목 유형
2601A Datasheet (145 KB) 데이터 시트
2601A Manual (656 KB) 매뉴얼

서비스

Repair

Our worldwide service centers provide fast cycle times, use only AE-qualified parts, and follow the original product's specifications and test procedures for the highest quality repair or calibration.

Agreement Term Options

Calibration and Alignment

Advanced Energy has the tools and processes to ensure your equipment continues to meet its original specifications.  Our products are calibrated at global AE service sites with proprietary technology designed to exceed industry standards​.

Agreement Term Options

24시간 (24/5) 고객 지원

전문 엔지니어의 기술지원을 받아보세요.

저희는 고객에게 우수한 고객 서비스와 기술 지원을 제공하기 위해 최선을 다하고 있습니다. 실시간 채팅 및 전화 지원을 통해 언제든지 자격을 갖춘 엔지니어에게 도움을 요청할 수 있습니다.
지금 지원 받기