跳至内容
tegam ®

Power Sensor Calibration Systems

Active

6 kHz to 50 GHz

Advanced Energy has condensed their experience with microwave calibration into convenient, accurate, and automated power sensor calibration systems that operate in the range of 6 kHz to 50 GHz. Our systems consist of RF power standards, RF power meters, and available power sensor calibration software. We also make turnkey packages that include the VNA, signal generator, power standards, workstation, software, and accessories required to enable immediate productivity. Our power sensor calibration software is ideal for automation and covers a variety of sensors from different manufacturers.Onsite installation and training are available with each complete system for a fast and trouble free start up.

特点

  • Systems avaiable in the 6 kHz to 18GHz, 26.5GHz, or 50 GHz range
  • PS-Cal Automation Software available
  • Calibrate sensors from multiple manufacturers
  • Onsite training available
  • Turnkey systems available
  • Lowest total uncertainty
  • Accurate and Repeatable RF power standards
  • Assembled in the USA

益处

  • Quickly enable productivity with automated software and training
  • Cost/benefit justification for ownership
  • One system calibrates a multiple sensors from various manufacturers

规格

Frequency Range: 6 kHz to 50 GHz
Power Range: 0.01 to 10 mW (-20 to +10 dBm)

库存检查

型号
Calibration Factor Accuracy (typical) Frequency Range Power Meters Included Sensor Connector Type Software Included Standards Included 购买
PMX18-012 Active, 联系我们
RF Power Sensor Calibration System 6 kHz to 18 GHz, Consists of: (1) 1830A (1) 2505A (1 each) CA-21-15, CA-14-2M
+/-(0.7 to 1.0)% from 6 kHz to 18 GHz 6 kHz to 18 GHz 1830A N- female No 2505A 购买
PMX18-CS-02-01 Active, 联系我们
Complete 9kHz to 18GHz Power Sensor Calibration System including Signal Generator, VNA, 2505A, 1830A, and accessories
+/-(0.7 to 1.0)% from 9 kHz to 18 GHz 9 kHz to 18 GHz 1830A N- female Yes 2505A 购买
PMX50-002 Active, 联系我们
RF Power Sensor Calibration System 10 MHz to 50 GHz, Consists of: (1) 1830A (1) 2510A (1 each) CA-21-15 and CA-14-2M
+/-(1.0 to 4.0)% from 10 MHz to 50 GHz 10 MHz to 50 GHz 1830A 2.4mm female No 2510A 购买
PMX50-014 Active, 联系我们
RF Power Sensor Calibration System 6 kHz to 50 GHz, Consists of: (2) 1830A (1) 2505A (1) 2510A (2 each) CA-21-15, CA-14-2M
+/-(0.7 to 4.0)% from 6 kHz to 50 GHz 6 kHz to 50 GHz 1830A x 2 N female and 2.4mm female No 2505A and 2510A 购买

Accessories Stock Check

Torque Wrench, 8mm, 5 in-lbs, SMA to 1585-1000
Torque Wrench, 3/4", 12 in-lbs, N (Standard Nut)
Attenuator, 20 dB, Type N Coax (M) to (F), with Data
Attenuator, 30dB, Type N Coax (M) to (F), with Data
Transport Case for 15XXA RF Power Standard

Transport case for 1505A and 1510A power standard
Note: 1510-910 is a standard item with a new purchase 
of the 1505A or 1510A

Adapter, 2.4 mm coax (M) to 2.92 mm (F) with Data
Adapter, 2.4 mm coax (M) to 3.5 mm (F) with Data
Test Cable with SMA Straight Plug Connectors, DC to 18 GHz, 3'
Low Loss RF Cable, 40 GHz, 2.92 mm (M) Connectors, 3'

Low loss RF cable, 40.0 GHz, 2.92mm male connectors
• Insertion loss max 3.6 dB

Low Loss RF Cable, 26.5 GHz, 3.5 mm (M) Connectors, 3'

Low loss RF cable, 26.5 GHz, 3.5 mm male connectors
• Insertion loss max 3.0 dB

Single Unit Rack Mount Kit, 1830A, F113XB & 25XXA Series
Dual Unit Rack Mount Kit, 1830A, F113XB & 25XXA Series
Transport Case for 1830A, F113X & 25XXA

Transport case for 1830A, F113X, 2505A, 2510A, M1130
and M1135

Torque Wrench, 8 mm, 8 in-lbs, for 3.5 mm, 2.92 mm and 2.4 mm
Adapter, 2.4 mm coax (M) to 2.92 mm (F) with Data
Torque Wrench, 8 mm, 8 in-lbs, for 3.5 mm, 2.92 mm and 2.4 mm
Attenuator, 30 dB, 2.4 mm Coax (M) to (F) with Data
Cable, USB A/A 2M
Calibration Cable for the 1830A with Spade Lugs, 48"
Cable, Voltage Bias and Heater, 1830A to 15XX/25XX, 15"

Heater cable (4-pin mini to 4-pin mini)
For use with the following combinations:
• 1806A connected to F1130A/B and F1135A/B
• 1830A connected to F1130A/B and F1135A/B

Cable, Voltage Bias and Heater, 1830A to 15XX/25XX, 48"

Heater cable (4-pin mini to 4-pin mini)
For use with the following combinations:
• 1806A connected to F1130A/B and F1135A/B
• 1830A connected to F1130A/B and F1135A/B

Low Loss RF Cable, 50GHz, 2.4 mm (M) Connectors, 12", for PMX
Low Loss RF Cable, 50GHz, 2.4 mm (M) Connectors, 36", for PMX
Cable, Sensor, 1830A to 8478B and 478A Sensor, 48"
Cable, 1830A to Unterminated Ends, 48"

Power Sensor Calibration Accessories

PM Series Accessories

技术文档

服务

Repair

Our worldwide service centers provide fast cycle times, use only AE-qualified parts, and follow the original product's specifications and test procedures for the highest quality repair or calibration.

Agreement Term Options

Calibration and Alignment

Advanced Energy has the tools and processes to ensure your equipment continues to meet its original specifications.  Our products are calibrated at global AE service sites with proprietary technology designed to exceed industry standards​.

Agreement Term Options

提供 24/5 支持

获取我们工程师的专家建议

我们致力于为客户提供优质的客户服务和技术支持。通过即时聊天和电话支持,您可以随时向合格的工程师寻求帮助。
立即获取支持